For Lease
SUITE 380
-
Time on Market
over 4 years
-
Space ID
1862395
-
Overview
300kW of UPS in 2N. 3 (60ton) CRAH units N+1 Cooling. 13’6” Slab to Slab floor heights with 18” raised floor. Dark fiber connectivity to The Westin Building. 15 fiber carriers. 24-hour on-site security officers along with digital video surveillance and personalized access card
-
Presented By
Cushman & Wakefield, Inc.Alex SmithJustin Baratz
SUITE 390
-
Time on Market
over 4 years
-
Space ID
1862396
-
Overview
Turn-key suite divisible to private cage or individual cabinets. 750 kVA total critical UPS Power in 2N. Two 400 kVA UPS and two 350 kVA UPS units. Dark fiber connectivity to The Westin Building. 15 fiber carriers. Built to Seismic Zone 3 Essential Facilities Criteria. 24-hour on-site security officers along with digital video surveillance and personalized access card
-
Presented By
Cushman & Wakefield, Inc.Alex SmithJustin Baratz
SUITE 400
-
Time on Market
over 4 years
-
Space ID
1862397
-
Overview
4,081 RSF floorplate. 600KW total power. 13’6” Slab to Slab floor heights with 18” raised floor. Dual connectivity risers provide redundant paths to the Meet Me Room. Connected to the Seattle Internet Exchange (SIX). Dark fiber connectivity to The Westin Building. 15 fiber carriers. Only purpose built data center in downtown Seattle. Built to Seismic Zone 3 Essential Facilities Criteria. 24-hour on-site security officers along with digital video surveillance and personalized access cards
-
Presented By
Cushman & Wakefield, Inc.Alex SmithJustin Baratz
SUITE 200
-
Time on Market
over 4 years
-
Space ID
1862393
-
Overview
10MW of primary power in 2N. Dual 4,000 amp 480 Volt risers from redundant Seattle City Light electrical vaults. 10.5MW of generator capacity with (3) 2MW generators and (2) 2.5MW generators. 73,000 gallon diesel storage capacity on-site. 1,840 tons of cooling in N+1 with (3) 920 ton chillers. Multiple chilled water risers. Dark fiber connectivity to The Westin Buiding. 15 fiber carriers. 24-hour on-site security officers along with digital video surveillance and personalized access card
-
Presented By
Cushman & Wakefield, Inc.Alex SmithJustin Baratz
SUITE 300
-
Time on Market
over 4 years
-
Space ID
1862394
-
Overview
1.2MW total power. (2)800 kVa UPS units in 2N (expandable). Ten (10) 40 ton CRAH units in N+1. 13’6” Slab to Slab floor heights with 18” raised floor
-
Presented By
Cushman & Wakefield, Inc.Alex SmithJustin Baratz
SUITE 500
-
Time on Market
over 4 years
-
Space ID
1862398
-
Overview
Powered shell. 3MW total power. 13’6” Slab to Slab floor heights with 18” raised floor. Multiple chilled water risers. Dual connectivity risers provide redundant paths to the Meet Me Room. Connected to the Seattle Internet Exchange (SIX). Dark fiber connectivity to The Westin Building. 15 fiber carriers. Only purpose built data center in downtown Seattle. Built to Seismic Zone 3 Essential Facilities Criteria. 24-hour on-site security officers along with digital video surveillance and personalized access cards
-
Presented By
Cushman & Wakefield, Inc.Alex SmithJustin Baratz
Property Details
- Property TypeOffice
- Submarket
- Year Built2001
- Total Available41,369RSF
- Largest Contiguous15,641RSF
- Number of Buildings2
- Building ClassA
- Property ID63035